Technology |
LASER scanner, time-of-flight measurement |
---|---|
Detection mode |
Presence |
Max. detection range |
4 m (diagonal) with reflectivity of 2% (i.e.: at W = 1.5m -> max. H = 3.7 m) |
Opening angle |
90° |
Angular resolution |
1.3° |
Typ. min. object size |
10 cm @ 4m (in proportion to object distance, DIP 2 = ON) |
Testbody |
700 mm × 300 mm × 200 mm (testbody CA according to EN 16005 & DIN 18650-1) |
Emission characteristics |
IR LASER: wavelength 905 nm; output power < 0.1 mW; CLASS 1 (IEC/EN 60825) |
Supply voltage |
12 - 24 V DC ± 15 % (The Equipment must be powered by an approved Class II SELV limited |
Power consumption |
≤ 2 W |
Response time |
50 ms |
Output |
2 electronic relays (galvanic isolation - polarity free) |
LED-signals |
1 bi-coloured LED: detection/output status |
Dimensions |
142 mm (L) × 85 mm (H) × 33 mm (D) ( mounting base + 7 mm ) |
Material - Colour |
PC/ASA - Black - Aluminum - White |
Tilt angles |
+2° to +10° (without mounting base) |
Protection degree |
IP54 (IEC/EN 60529) |
Temperature range |
-30°C to +60°C if powered |
Humidity |
0-95 % non-condensing |
Vibrations |
< 2 G |
De specificaties kunnen zonder voorafgaande kennisgeving worden gewijzigd. Gemeten onder specifieke omstandigheden.