i-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingairporthospitalsindustrylogisticsretailArtboardempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

Vi har upptäckt att du kommer från en annan region. Välj ett av följande alternative:

Välj önskad marknad och språk

Go
Eller

LZR®-FLATSCAN REV PZ

Säkerhetssensor för karuselldörrar
Teknik Laser
Färger:

Beskrivning

LZR-FLATSCAN REV PZ är den första lasersäkerhetssensorn som är specifikt utformad för automatiska karuselldörrar. Den använder tekniken flygtid och skapar 400 mätpunkter för att ge användarna ett fullständigt skydd, samtidigt som dörrens funktion säkerställs.

Funktioner

Oberoende av golv och miljö

Lasertekniken garanterar stabil funktion oavsett typ av golvbelägg-ning (spaltgolv, metallnät, absorberande matta, reflekterande golv, hala ytor) och väderförhållanden

Snabb, intuitiv installation

Storleken på detektionsfältet definieras genom två enkla handrörel-ser. Områdets höjd och bredd beräknas automatiskt.

Visuella hjälpmedel

Under installationsprocessen kan man aktivera två synliga strålar som hjälp vid justering av detektionsfältet.

Två områden

Vid behov kan man tilldela två områden till separata utgångar för olika funktioner (t.ex. sakta ner och stanna).

Detekteringsfält
Tabell över specifikationer

Technology

LASER scanner, time-of-flight measurement

 

Detection mode

Presence

 

Max. installation height

3.5 m (DIN 18650-1)
4m (EN 16005)
5m (with reflectivity of 8%)

 

Opening angle

90°

 

Angular resolution

0.23° (400 spots within 90°)

 

Testbody

700 mm x 300 mm x 200 mm (testbody CA according to EN 16005 & DIN 18650-1 < 4 m) 50mm cylinder (testbody CB according to DIN 18650-1 < 3.5 m)

 

Optical characteristics
IEC/EN 60825-1

Wavelength 905 nm; output power 0.10 mW ; CLASS 1
Wavelength 635 nm; output power 0.95 mW ; CLASS 2 - visible spot

 

Supply voltage

12-24V DC ± 15%

 

Power consumption

≤ 2.2 W

 

Response time

Max. 90 ms

 

Output

1 optocoupler ( galvanic isolation - polarity free )
Max. switching voltage: 42V AC/ 60V DC
Max. switching current: 100 mA
1 Relay ( free of potential change-over contact )
Max. contact voltage: 60V AC / 125V DC
Max. contact current: 1.0A ( resistive )
Max. switching power: 30W ( DC ) / 60VA ( AC )

 

LED-signals

1 bi-coloured LED: detection/output status

 

Dimensions
Recessed version
Surface version

178 mm (L) × 85 mm (H) × 53 mm (D)
168 mm (L) × 93 mm (H) × 42.5 mm (D)

 

Material - Colour

PC/ABS - Black / Aluminum

 

Tilt angles

0° to +5°

 

Protection degree

IP54 (IEC/EN 60529)

 

Temperature range

-30°C to +60°C if powered

 

Humidity

0-95 % non-condensing

 

Vibrations

< 2 G

 

Compliance

Denna produkt överensstämmer med all tillämplig EU-lagstiftning. Se försäkran om överensstämmelse för mer information.

 
Versioner
  • LZR®-FLATSCAN REV PZ RECESSED

    infälld monteringsversion

  • LZR®-FLATSCAN REV PZ SURFACE

    ytmonterad version

Tillbehör
  • LZR®-FLATSCAN REV SPACER

    Spacer för LZR®-FLATSCAN REV PZ RECESSED

Installationer

Två synliga punkter hjälper till vid justering av detektionsfältets position.
• Detektionsfältets vinkel kan justeras: 0–5 grader.
• Med hjälp av fjärrkontroll kan man justera ytterligare parametrar.