Technology |
LASER scanner, time-of-flight measurement |
---|---|
Max. detection range |
max. 2,50 m (height) and 2,50 m (width) with reflectivity of 2% |
Field of view |
90° |
Angular resolution |
1.3° |
Typ. min. object size (Door wing protection) |
≤ 10 cm |
Testbody |
700 mm × 300 mm × 200 mm (testbody CA according to EN 16005) |
Optical characteristics (IEC/EN 60825-1:2014) |
IR LASER: wavelength 905 nm; output power < 0.1 mW; Class 1 |
Supply voltage* |
12 - 24 V DC ± 15 % |
Power consumption |
≤ 2 W |
Response time |
max. 50 ms |
Output* Max. switching voltage Max. switching current |
2 electronic relays (galvanic isolation - polarity free) 30V AC / 42V DC 100 mA |
LED-signals |
1 bi-coloured LED: detection/output status |
Dimensions |
146 mm (L) × 85 mm (H) × 32 mm (D) (mounting base + 7 mm) |
Material - Colour |
PC/ASA - Black |
Tilt angles |
+2° to +10° (without mounting bracket) |
Protection degree |
IP54 (IEC/EN 60529) |
Temperature range |
-30°C to +60°C if powered |
Humidity |
0-95 % non-condensing |
Vibrations |
< 2 G |
Conformity |
This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information. |
Specifications are subject to change without prior notice. All values measured in specific conditions.
* External electrical sources must be within specified voltages, max 15W and ensure double insulation from primary voltages.