Technology |
LASER scanner, time-of-flight measurement, background analysis |
---|---|
Detection mode |
Presence |
Max. detection range |
4 m (diagonal) (i.e. : at W = 3.7 m -> max. H = 1.5 m) |
Number of curtains |
1 |
Measurement points |
400 |
Angular resolution |
0,27° |
Angular coverage |
110° |
Min. detected object size |
2 cm (depending on the settings and the installation) |
Optical characteristics |
IR LASER : Wavelength 905 nm; output power < 0.1mW; Class 1 |
Supply voltage |
12-24V DC ± 15% (The Equipment must be powered by a SELV limited power source ensuring |
Power consumption |
≤ 2 W |
Typ. response time |
400 ms |
Peak current at power-on |
0.8 A (max. 20 ms @ 24 VDC) |
Cable length |
5 m |
Output |
2 solid state relays (galvanic isolation - polarity free) |
Input |
1 optocoupler (galvanic isolated - polarity free) |
LED-signals |
1 Tri-coloured LED: detection/output status |
Dimensions |
142 mm (L) × 85 mm (H) × 33 mm (D) ( mounting base + 14 mm ) |
Material - Colour |
PC/ASA - Black - Aluminium - White |
Tilt angles |
-2° to +6° (with mounting base) |
Protection degree |
IP54 |
Temperature range |
-30°C to +60°C if powered; -10°C to +60°C without power |
Humidity |
0-95 % non-condensing |
Vibrations |
< 2 G |
Norm conformity |
This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information. |
Specifications are subject to changes without prior notice.
All values measured in specific conditions.