Technology |
Laser scanner, time-of-flight measurement (4 laser curtains) |
---|---|
Detection mode |
Motion and presence |
Max. detection range |
9.9 m x 9.9 m |
Remission factor |
> 2 % |
Angular resolution |
0,3516 ° |
Optical characteristics |
IR LASER: Wavelength 905 nm; output power <0.10mW; Class 1 |
Supply voltage |
10-35 V DC @ sensor side (to be operated from SELV compatible power supplies only) |
Power consumption |
< 5 W |
Peak current at power-on |
1.8 A (max. 80 ms @ 35 V) |
Cable length |
5 m (standard), max.: 10 m |
Response time |
|
Output |
2 electronic relays (galvanic isolated - polarity free) |
Test input |
1 optocoupler (galvanic isolated - polarity free) |
LED-signal |
1 blue LED: power-on status; 1 orange LED: error status; |
Dimensions |
125 mm (D) x 93 mm (W) x 70 mm (H) (with mounting bracket + 14 mm) |
Material |
PC/ASA |
Colour |
Black |
Mounting angles on bracket |
-45 °, 0 °, 45 ° |
Rotation angles on bracket |
-5 ° to +5 ° (lockable) |
Tilt angles on bracket |
-3 ° to +3 ° |
Protection degree |
IP65 (IEC/EN60529) |
Temperature range |
-30 °C to +60 °C if powered; -10 °C to +60 °C unpowered |
Humidity |
0-95 % non-condensing |
Vibrations |
< 2 G |
Pollution on front screens |
max. 30 %; homogenous |
Conformity |
This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information. |
Specifications are subject to change without prior notice – All values measured in specific conditions.