Technology |
Laser scanner, time-of-flight measurement; |
|---|---|
Scanning range |
0.08 – 25 m; 7 m @ 1.8% reflectivity; 15 m @ 10% reflectivity; |
Curtain |
1 |
Scanning angle |
275° |
Angular resolution |
0.2° @ 80 Hz |
Measurement accuracy |
± 10 mm* |
Detection fields |
Number of field sets: 16 |
Supply voltage** |
12 – 24 V DC, - 10% / + 30% |
Interface |
PNP inputs/outputs; Ethernet, TCP/IP; USB: 2.0, Type-C |
Digital inputs/outputs |
Inputs: 4 x PNP; Outputs: 5 x PNP (Max. 30 V DC, 80 mA) |
On/Off delay time |
0 - 10 000 ms, configurable |
Degree of protection |
IP67 (only with the USB port cover in place, IEC/EN 60529) |
Ambient conditions |
100,000 lux ambent light; 3,000 lux (IEC 61496-3) |
Conformity |
This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information. |
* Typical value at 10% reflectivity up to 7 m scanning range or as specified; real values depends on ambient conditions and the target object.
** External electrical sources must be within specified voltages and ensure double insulation from primary voltages. For UL compliance, the device shall be supplied exclusively by class 2 power supplies.