i-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitairporthospitalsindustrylogisticsretailArtboardempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

Technology

LASER scanner, time-of-flight measurement (7 laser curtains)

Detection mode

Motion, presence, height and speed

Max. detection field

Width: 1 x mounting height; Depth: 1 x mounting height

Thickness of first curtain

0.5 cm / m (mounting height)

Mounting height

2 m to 10 m

Min. reflectivity factor

> 2 % (of floor and object) (measured at max. 6 m in safety field)

Min. object size

70 cm x 30 cm x 20 cm

Emission characteristics
(IEC 60825-1)

IR LASER: Wavelength 905 nm; output power <0.1 mW; Class 1 Visible LASER: Wavelength 635 nm; output power <1 mW; Class 2

Bluetooth communication

Operating bandwidth: 2402 MHz – 2480 MHz
Maximum transmitted power: 12 dBm

Supply voltage

12 V - 24 V AC -10%/+20% ; 12 V - 30 V DC -10%/+20% @ sensor terminal (The
Equipment must be powered by an approved Class II SELV limited power source. This requirement
consists of the need for double insulation between primary voltages and the Equipment supply.
The supply current should be limited to 1.5 A)

Power consumption

heating off: < 2.5 W heating auto: typ. < 10 W, max. 15 W

Response time

Typ. 230 ms; max. 800 ms (depending on immunity settings)

Output

2 solid-state relays ( galvanic isolation - polarity free )
24 V AC/ 30 V DC (max. switching voltage) - 100 mA (max. switching current)
- in switching mode: NO/NC
- in frequency mode: pulsed signal (f= 100 Hz +/- 10%)
1 electro-mechanic relay (galvanic isolation - polarity free)
42 V AC/DC (max. switching voltage) - 500 mA (max. switching current)

Test input

30 V DC (max. switching voltage) - low < 1 V, high > 10 V (voltage threshold)

LED-signals

3 coloured LEDs

Dimensions

45° to the right, 15° to the left ( lockable )

Material / Colour

159 mm (H) x 208 mm (W) x 127 mm (D)

Rotation angles on bracket

PC/ASA / Black

Tilt angles on bracket

45° to the right, 15° to the left ( lockable )

Protection degree

IP65

Temperature range

-30 °C to +60 °C

Norm conformity

This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information.

Specifications are subject to changes without prior notice – Measured in specific conditions.