airporthospitalsindustrylogisticsretailArtboardi-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Technical specifications

Technology

Microwave motion sensor

Radiated frequency

24.150 GHz

Radiated power

< 20 dBm EIRP

Radiated power density

< 5mW/cm2

Detection range (hand)

+/- 10 to 60 cm if movement towards sensor at 90° (adjustable)*

Detection mode

Motion (bidirectional)

Speed of target to create detection

Min. 5Hz or +/- 3cm/s, Max. 200Hz or +/- 1.2m/s

Supply voltage**

12 - 24V AC +/- 10%(50 - 60 Hz)
12 - 24V DC +30% / - 10%

Power consumption

< 1.5W

Output**
Max. voltage
Max. current
Max. switching power

Relay with switch-over contact (voltage free)
60V DC / 30 VAC
1A (resistive)
15W

Output holdtime

0.5s (in PULSE mode)

Temperature range

-20°C to +55°C

Degree of protection

IP65

Material

PC

Wiring cable

Stranded cable up to 16 AWG - 1.5mm2

Norm conformity

This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information.

Specifications are subject to changes without prior notice
Measured in specific conditions.

* An adjustment of the detection field below 10 cm is possible but the detection capability of the sensor can not be guaranteed.
** External electrical sources must be within specified voltages, max 15W and ensure double insulation from primary voltages.

need more information Contact us

Subscribe to our newsletter