airporthospitalsindustrylogisticsretailArtboardi-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

Technology

active infrared, microprocessor

Mounting height

min. 0.2 m above the floor

Distance between beams

min. 0.3 m (crossed beams)

Distance in relation to the door plane

2 cm

Minimum range

1 m

Maximum range

5 m - for min. mounting height of 0.2 m; 10 m - for min. mounting height of 0.4 m

Half-opening angle of the beam

Detection mode

presence (beam interruption)

Output response time

MICROCELL ONE & TWO
≤ 40 ms

MICROCELL THREE
≤ 10 ms (setting or interruption of the beam)

Hold time

300 ms

Supply voltage

MICROCELL ONE & TWO
12-24 V AC ±10% - 12-24 V DC –5/+30%

MICROCELL THREE
12-24 V DC –5/+20%

Current consumption

< 100 mA

Output
max. voltage
max. current
max. switching power / voltage drop

MICROCELL ONE & TWO
1 or 2 relays (free potential contact)
50 V DC / 50 V AC
1 A (resistive)
30 W (DC) / 50 VA (AC)

MICROCELL THREE
open collector transistor (NPN or PNP)
30 V DC
20 mA
< 2 V at 20 mA

Signal

1 LED per barrier

Temperature range

–20°C to +55°C

Degree of protection

IP 65 (DIN 40050)

Dimensions heads
Dimensions control box

housing : 10 mm (built-in) x 12.4 mm (diameter); collar : diameter 15.6 mm
94 mm (L) x 52 mm (W) x 28 mm (H)

Cable length

5 m (10 m optional)

Weight emitter - receiver
Weight control box

0.140 Kg (5 m) / 0.270 kg (10 m)
0.060 Kg

Material

ABS

Housing color