Techhnology |
LASER scanner, time-of-flight measurement |
---|---|
Detection mode |
Presence |
Installation height |
Max : 5m Min : 2m |
Opening angle |
90° |
Angular resolution |
0.23° (400 spots within 90°) |
Optical characteristics |
Wavelength 905 mm; output power < 0.1mW ; CLASS 1 |
Supply voltage |
12-24V DC ± 15% |
Power comsuption |
≤ 2.2 W |
Response time |
Max. 90 ms |
Output |
1 optocoupler (galvanic isolation - polarity free) |
LED-signals |
1 bi-coloured LED: detection/output status |
Dimensions |
178 mm (L) × 85 mm (H) × 53 mm (D) |
Material - Colour |
PC/ABS - Black/Aluminum |
Tilt angles |
0° to +5° |
Protection degree |
IP54 (IEC/EN 60529) |
Temperature range |
-30°C to +60°C if powered |
Humidity |
0-95% non-condensing |
Vibrations |
< 2 G |
Conformity |
This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information. |