Technology |
LASER scanner, time-of-flight measurement |
||
---|---|---|---|
Detection mode |
Presence |
||
Installation height |
Min : 2m |
Pinch zone (fixed installation) |
Sword zone (moving installation) |
Field of view |
90° |
||
Angular resolution |
0.23° ( 400 spots within 90° ) |
||
Testbody |
Testbody CA (EN & DIN) : 700 mm x 300 mm x 200 mm |
||
Optical characteristics |
Wavelength 905 nm; output power < 0.1 mW ; CLASS 1
|
||
Supply voltage* |
12-24V DC ± 15% |
||
Power consumption |
≤ 2.2 W |
||
Response time |
Max. 90 ms |
||
Output* |
1 optocoupler ( galvanic isolation - polarity free ) |
||
LED-signals |
1 bi-coloured LED: detection/output status |
||
Dimensions |
178 mm (L) × 85 mm (H) × 53 mm (D) |
||
Material - Colour |
PC/ABS - Black / Aluminum |
||
Tilt angles |
0° to +5° |
||
Protection degree |
IP54 ( EN 60529 ) |
||
Temperature range |
-30°C to +60°C if powered |
||
Humidity |
-95% non-condensing |
||
Vibrations |
< 2 G |
||
Conformity |
This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information. |
*External electrical sources must be within specified voltages, max 15W and ensure double insulation from primary voltages.
Specifications are subject to change without prior notice. All values are measured in specific conditions.