Technology |
LASER scanner, time-of-flight measurement |
---|---|
Detection mode |
Presence |
Max. detection range |
4 m (diagonal) with reflectivity of 2% (i.e. : at W = 1.5m -> max. H = 3.7 m) |
Field of view |
Door wing safety: 90° / Pinch zone safety: 16° |
Angular resolution |
Door wing safety: 1.3°/ Pinch zone safety: 0.2° |
Typ. min. object size |
Door wing safety: 10 cm @ 4m (in proportion to object distance, DIP 2 = ON) |
Testbody |
700 mm × 300 mm × 200 mm (testbody CA according to EN 16005 & DIN 18650) |
Emission characteristics |
IR LASER: Wavelength 905 nm; max. output pulse power 25 W; Class 1 |
Supply voltage |
12 - 24 V DC ± 15 % |
Power consumption |
≤ 2 W |
Response time |
Door wing safety: max. 50 ms / Pinch zone safety: max. 90 ms |
Output |
2 electronic relays (galvanic isolation - polarity free) |
LED-signals |
1 bi-coloured LED: detection/output status |
Dimensions |
142 mm (L) × 85 mm (H) × 33 mm (D) (mounting bracket + 7 mm) |
Material - Colour |
PC/ASA - Black - Aluminium - White |
Tilt angles |
+2° à +10° (without mounting bracket) |
Protection degree |
IP54 (EN 60529) |
Temperature range |
-30°C to +60°C if powered |
Humidity |
0-95 % non-condensing |
Vibrations |
< 2 G |
Min. door wing speed |
2°/sec |
Norm conformity |
This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information. |
Specifications are subject to changes without prior notice – Measured in specific conditions.